Search
Box type air-cooled chiller
[product features]: the compressor of box type air-cooled chiller adopts scroll type fully enclosed compressor and electric control components, and is equipped with condenser and evaporator made of high-efficiency and high-quality copper tubes for heat exchange. The box type air-cooled chiller adopts the air cooling mode, eliminating the cooling tower, cooling water pump and pipeline system necessary for the cooling water system, avoiding condenser scaling and water pipe blockage in areas with poor water quality, and saving water resources< Br / >
[application field]: industrial fluid temperature control
Box type water-cooled refrigerator
[product features]: the water-cooled chiller is a kind of industrial chiller, which is named because its own heat dissipation is through the external cooling tower to provide water. Compared with the air-cooled chiller, the unit has the advantages of not being affected by the external environment and slightly larger cooling capacity than the air-cooled chiller. It is suitable for occasions where the installation environment is not very abundant< Br / >
[application field]: industrial fluid temperature control
Box type air-cooled refrigerator
[product features]: the compressor of the box type air-cooled refrigerator adopts the scroll type fully enclosed compressor and electric control components, and is equipped with a condenser and evaporator made of high-efficiency and high-quality copper tubes for heat exchange. The box type air-cooled chiller adopts the air cooling mode, eliminating the cooling tower, cooling water pump and pipeline system necessary for the cooling water system, avoiding condenser scaling and water pipe blockage in areas with poor water quality, and saving water resources< Br / >
[application field]: industrial fluid temperature control
Air cooled explosion-proof refrigerator
[product features]: the whole machine is explosion-proof. Explosion proof certificate issued by national explosion proof electrical product quality supervision and inspection center
[application field]: industrial fluid temperature control
[application field]: industrial fluid temperature control
Box type water-cooled chiller
Air cooled explosion-proof water chiller
LRD series for rubber and plastic (98 ℃)
characteristic
Temperature control range: inlet water temperature +15 ℃ ~ 98 ℃
Return water temperature display
Heating power switching function
Automatic exhaust function after startup
Hot water by-pass pressure relief circuit
Stainless steel integrated pipeline reduces pipe resistance and rust scale
Siemens Omron Fuji Abb Schneider
Isolated electrical control box to extend the service life of electrical appliances
Multi point temperature control can be customized
Pump horsepower and heating power can be customized
Explosion proof device (optional)
Air blowing and water return function (optional)
Negative pressure system operation (optional)
Instant cooling shutdown function (optional)
RS485 communication function to realize automatic management (optional)
PLC control, system dynamic flow chart display, pressure / flow adjustable and controllable (optional)
Perfect safety protection, fault display, repair and maintenance without professional personnel
LWM series (120 ℃)
characteristic
Temperature control range: inlet water temperature +15 ℃ ~ 120 ℃
Return water temperature display
Heating power switching function
Automatic exhaust function after startup
Hot water by-pass pressure relief circuit
Stainless steel integrated pipeline reduces pipe resistance and rust scale
Siemens Omron Fuji Abb Schneider
Isolated electrical control box to extend the service life of electrical appliances
Multi point temperature control can be customized
Pump horsepower and heating power can be customized
Explosion proof device (optional)
Air blowing and water return function (optional)
Negative pressure system operation (optional)
Instant cooling shutdown function (optional)
RS485 communication function to realize automatic management (optional)
PLC control, system dynamic flow chart display (optional)
Perfect safety protection, fault display, repair and maintenance without professional personnel
Lewt series (180 ℃)
characteristic
Temperature control range: inlet water temperature +15 ℃ ~ 180 ℃
Return water temperature display
Heating power switching function
Automatic exhaust function after startup
Hot water by-pass pressure relief circuit
Stainless steel integrated pipeline reduces pipe resistance and rust scale
Siemens Omron Fuji Abb Schneider
Isolated electrical control box to extend the service life of electrical appliances
Multi point temperature control can be customized
Pump horsepower and heating power can be customized
Explosion proof device (optional)
Air blowing and water return function (optional)
Negative pressure system operation (optional)
Instant cooling shutdown function (optional)
RS485 communication function to realize automatic management (optional)
PLC control, system dynamic flow chart display (optional)
Perfect safety protection, fault display, repair and maintenance without professional personnel
Box type chiller
characteristic
Compressor head imported from Europe and America
Oxygen free welding method is adopted for copper pipe
Imported advanced components with long service life
High efficiency evaporator and condenser can save more than 30% energy
Two sets of compressor heads are used above C-15, which can be used separately or jointly
Siemens Omron Fuji Abb Schneider
RS485 communication function to realize automatic management (optional)
PLC control, system dynamic flow chart display, pressure / flow adjustable and controllable (optional)
The
Remarks:
1. refrigeration conditions in the above table: chilled water inlet temperature is 12 ℃, chilled water outlet temperature is 7 ℃, cooling inlet temperature is 30 ℃, and outlet temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
Remarks:
1. refrigeration conditions in the above table: chilled water inlet temperature 12 ℃, chilled water outlet temperature 7 ℃, ambient temperature 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is 0 ℃, the outlet water temperature is -5 ℃, the cooling inlet water temperature is 30 ℃, and the outlet water temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is 0 ℃, the outlet water temperature of cold water is -5 ℃, and the ambient temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is -10 ℃, the outlet water temperature is -15 ℃, the cooling inlet water temperature is 30 ℃, and the outlet water temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the unit performance parameters with R404A as refrigerant;
4. specifications and dimensions may change due to product improvement without further notice.
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is -10 ℃, the outlet water temperature of cold water is -15 ℃, and the ambient temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the unit performance parameters with R404A as refrigerant;
4. specifications and dimensions may change due to product improvement without further notice.
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is -20 ℃, the outlet water temperature is -25 ℃, the cooling inlet water temperature is 30 ℃, and the outlet water temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the unit performance parameters with R404A as refrigerant;
4. specifications and dimensions may change due to product improvement without further notice.
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is -20 ℃, the outlet water temperature of cold water is -25 ℃, and the ambient temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
Water cooled screw chiller
characteristic
Excellent performance and easy installation
Compressor head imported from Europe and America
Oxygen free welding method is adopted for copper pipe
Imported advanced components with long service life
High efficiency evaporator and condenser can save more than 30% energy
Siemens Omron Fuji Abb Schneide
RS485 communication function to realize automatic management (optional)
Control mode: imported PLC control
Perfect safety protection, fault display, low operation and maintenance costs
The
Water cooled screw chiller BSL series (single machine /7 ° C)
Remarks:
1. refrigeration conditions in the above table: cold water inlet temperature: 12 ℃, cold water outlet temperature: 7 ℃, cooling inlet temperature: 30 ℃, outlet temperature: 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and overall dimensions may change due to product improvement without further notice
The
Water cooled screw chiller BSL series (dual type /7 ° C)
Remarks:
1. refrigeration conditions in the above table: cold water inlet temperature: 12 ℃, cold water outlet temperature: 7 ℃, cooling inlet temperature: 30 ℃, outlet temperature: 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
The
Water cooled screw chiller BSL series (single machine type /-5 ℃)
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is 0 ℃, the outlet water temperature of cold water is -5 ℃, the inlet water temperature of cooling water is 30 ℃, and the outlet water temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
The
Water cooled screw chiller BSL series (dual model /-5 ℃)
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is 0 ℃, the outlet water temperature of cold water is -5 ℃, the inlet water temperature of cooling water is 30 ℃, and the outlet water temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
The
Water cooled screw chiller BSL series (single machine type /-15 ℃)
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is -10 ℃, the outlet water temperature of cold water is -15 ℃, the inlet water temperature of cooling water is 30 ℃, and the outlet water temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R404A and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
The
Water cooled screw chiller BSL series (dual model /-15 ℃)
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is -10 ℃, the outlet water temperature of cold water is -15 ℃, the inlet water temperature of cooling water is 30 ℃, and the outlet water temperature is 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R404A and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
The
Water cooled screw chiller BSL series (single machine type /-25 ℃)
Remarks:
1. refrigeration conditions in the above table: the inlet water temperature of frozen glycol aqueous solution is -20 ℃, the outlet
Air cooled screw chiller
Features:
Excellent performance and easy installation
Compressor head imported from Europe and America
Oxygen free welding method is adopted for copper pipe
Imported advanced components with long service life
High efficiency evaporator and condenser can save more than 30% energy
Siemens Omron Fuji Abb Schneider
RS485 communication function to realize automatic management (optional)
Control mode: imported PLC control
Perfect safety protection, fault display, low operation and maintenance costs
The
Air cooled screw chiller BSL series (single machine /7 ℃)
Remarks:
1. refrigeration conditions in the above table: cold water inlet temperature 12 ℃, cold water outlet temperature 7 ℃, ambient temperature 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
The
Air cooled screw chiller BSL series (single machine type /-5 ℃)
Remarks:
1. refrigeration conditions in the above table: cold water inlet temperature 0 ℃, cold water outlet temperature -5 ℃, ambient temperature 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R407C and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
The
Air cooled screw chiller BSL series (single machine type /-15 ℃)
Remarks:
1. refrigeration conditions in the above table: cold water inlet temperature -10 ℃, cold water outlet temperature -15 ℃, ambient temperature 35 ℃;
2. power supply system: 3p-380v-50hz, allowable voltage fluctuation ± 10%, allowable phase to phase voltage difference ± 2%;
3. the above data are the performance parameters of the unit with R22 as the refrigerant. If you need R404A and other refrigerants, please contact us;
4. specifications and dimensions may change due to product improvement without further notice.
Link: Nanjing lidesheng Machinery Co., Ltd. - Nanjing Bosheng refrigeration equipment Co., Ltd
Address: No. 59-2, Xiushan Road, Gaochun Economic Development Zone, Nanjing
Tel: 025-6890-5285
Mobile: 15852924785
Jiangsu rongyida Temperature Control Technology Co., Ltd